ConstructSim Executive Client Help

To Review SPURT.mdb

  1. From the ProjectData\UnitRates folder, open SPURT.mdb.
  2. Open the TypicalSteps table.


    This table contains the configuration of tasks per activity model.

  3. Right-click on one activity type in the Activity Type column and apply a filter for it, following the prompts in the window.
  4. In the ISO Component column, right-click one type and apply a filter for it.
    Note:
    • The typical steps for a PIPE Install Activity model for the  component of PIPE_SPOOL  are defined in the Step Description column.

    • The Step Spread Factor column represents how the standard unit rate will be distributed across the typical steps.

    • The man-hours come from the Unit Rates table in the SPURT.mdb. The unit rates table contains man–hours that are derived from the Page and Nations Estimator’s Piping Man-Hour Manual.

  5. Open the UnitRates table in SPURT.mdb and filter for a component in the Component Type column.
  6. In the UnitRates table, filter on the Activity Type column for the desired type.